Hand grip strength variability during serial testing as an entropic biomarker of aging: a Poincaré plot analysis

Abstract

Background

The Poincaré plot method can be used for both qualitative and quantitative assessment of self-similarity in usually periodic functions, hence the idea of applying it to the study of homeostasis of living organisms. From the analysis of numerous scientific data, it can be concluded that hand functionality can be correlated with the state of the human body as a biological system exposed to various forms of ontogenetic stress.

Methods

We used the Poincaré plot method to analyze the variability of hand grip strength (HGS), as an entropic biomarker of aging, during 60 repetitive tests of the dominant and nondominant hand, in young and older healthy subjects. An observational cross-sectional study was performed on 80 young adults (18–22 years old, mean age 20.01 years) and 80 older people (65–69 years old, mean age 67.13 years), with a sex ratio of 1:1 for both groups. For statistical analysis, we applied univariate descriptive statistics and inferential statistics (Shapiro–Wilk test, Mann–Whitney U-test for independent large samples, with the determination of the effect size coefficient r, and simple linear regression. We calculated the effect of fatigue and the Poincaré indices SD1, SD2, SD1/SD2 and the area of the fitting ellipse (AFE) for the test values of each subject.

Results

The analysis of the differences between groups revealed statistically significant results for most HGS-derived indices (p ≤ 0.05), and the magnitude of the differences indicated, in most situations, a large effect size (r > 0.5). Our results demonstrate that the proposed repetitive HGS testing indicates relevant differences between young and older healthy subjects. Through the mathematical modeling of data and the application of the concept of entropy, we provide arguments supporting this new design of HGS testing.

Conclusions

Our results indicate that the variability of HGS during serial testing, which reflects complex repetitive biomechanical functions, represents an efficient indicator for differentiation between young and older hand function patterns from an entropic perspective. In practical terms, the variability of HGS, evaluated by the new serial testing design, can be considered an attractive and relatively simple biomarker to use for gerontological studies.

Peer Review reports

Background

The Poincaré plot as a tool for mathematical modeling of data

The Poincaré plot defines a computational graphic tool (scattergram-type plot) for Cartesian representation of a series of data with dynamic nonlinear evolution. The application of the method refers, in particular, to the study of the time evolution of nonlinear phenomena that characterize open physical systems.

The Poincaré plot is based on the concept of constructing a return map (recurrence plot) of a time series of data and quantifies the recurrence, self-similarity, or periodicity of state variables of systems [1]. Practically, such analyses of the behavior of physical systems under different circumstances appeal to the concept of entropy. Entropy refers to the degree of disorder that characterizes a physical system, which can be appreciated in terms of the randomness and predictability of its evolution over time. Thus, greater entropy implies an increased randomness and a lower system order [2].

By analysing the geometric characteristics of the graphs plotted by the Poincaré method, it is possible to extract quantitative variables that help to characterize the dynamics of the systems taken into account [3]. Additionally, through complex statistical calculations, correlations across multiple spatiotemporal scales can be determined, which help to identify fractal dynamics [4]. Overall, using the proposed method, it is possible to achieve an entropy-based analysis of complex time series of data.

In mathematics, the Poincaré plot consists of a geometrical representation in the Cartesian plane of a time data string of the type x1, x2, x3, …, xn. Each value xi, where i = 1 … .n, refers to a time-based state of nonlinear evolution of a defined characteristic of a system. The return map of the data includes a plot for the following pairs of coordinates: (x1, x2), (x2, x3), … (xi, xi + 1)..., (xn-1, xn). Usually, the resulting plot is an ellipse, which can provide two important descriptors for a quantitative analysis of the dynamics of the time series data: SD1 and SD2, which in fact represent the minor and the major axes of the ellipse, respectively [5].

SD1 and SD2 are calculated through formulas that incorporate the standard deviation of the time series. Practically, SD1 represents the standard deviation (dispersion) of the distances of points from the major axis of the ellipse and indicates the short-term variability of the time series of data. SD2 represents the standard deviation (dispersion) from the minor axis of the ellipse and indicates the long-term variability of the time series of data [6].

The formulas for the two parameters are the following [5,6,7]:

$$ \mathrm{SD}1=\frac{\sqrt{2}}{2}\ast SD\left({x}_n-{x}_{n+1}\right) $$
$$ \mathrm{SD}2=\sqrt{2 SD{\left({x}_n\right)}^2-\frac{1}{2} SD{\left({x}_n-{x}_{n+1}\right)}^2} $$

where SD (xn – xn + 1) represents the standard deviation of the time series xn – xn + 1 and SD (xn) the standard deviation of the time series xn.

Another statistical indicator for the analysis of dynamic data evolution is the ratio SD1/SD2, which measures the relative balance between short- and long-term variabilities of the time series of data [8]. For this reason, SD1/SD2 reflects the clarity and linearity of the scatter pattern [9]. For statistical analysis, the area of the fitting ellipse (AFE) has been proposed, which is calculated by the formula AFE = πSD1SD2 [7].

The utility of the Poincaré plot is justified by the fact that the initial qualitative analysis of a nonlinear distribution of data, by tracing the ellipse, can be transformed into a quantitative analysis in terms of linear statistics by calculating SD1 and SD2.

Applications of Poincaré plot in the analysis of the biological systems dynamics

Because living organisms can be assimilated to open biological systems, various forms of their entropic behaviors have been proposed from the perspective of particular dynamic physiological parameters [10].

In this regard, the Poincaré plot has proven to be widely applicable in the field of human biology, for scale entropy analysis of complex physiologic time series [11] and for control systems involved in their complex regulation [12].

Traditionally, Poincaré plots have been used to represent biomedical signals such as heart rate and respiratory pattern variabilities [1]. Most studies of this kind are aimed at studying beat-to-beat heart rate variability in clinical circumstances. In this way, representations of R-R intervals can be extracted from serial electrocardiographic records.

The bivariate segmented Poincaré plot analysis, which is a variant derived from the classic one, is used to study the interactions between beat-to-beat RR intervals and its temporal enclosed systolic blood pressure time series [13].

At the respiratory level, the utility of the Poincaré plot analysis has been demonstrated for the exploration of the breathing pattern variability in terms of total breath duration, tidal volume, inspiratory time, expiratory time, and peak inspiratory flow [14, 15].

The Poincaré plot method was also proposed for the study of blood pressure variability [16], glucose variability from continuous glucose monitoring systems [7, 17], and the variability of some electroencephalographic paths [18, 19], polysomnography paths [9], plethysmography data [20], electromyography or electrohysterography data [6].

A new perspective for developing the Poincaré plot method has been projected for the purpose of comparing dynamical systems concepts and techniques for biomechanical analysis [4]. Thus, it is known that human movement implies entropy changes because body systems are exposed to various forms of stress constraints during locomotion.

In this way, the Poincaré plot analysis was proposed to characterize the mechanical time series fluctuations of gait. More explicitly, it quantified the foot clearance variability of patients in different clinical contexts (older people, neurodegenerative diseases, stroke etc.) [6, 21, 22] or other gait parameters (swing time, step length, and step width) [23]. For gait analysis through the Poincaré plot method, selected gait data signals (stride intervals) have been proposed for recording by some authors using force-sensitive resistors. These authors demonstrated that in healthy subjects, the parameters SD1 and SD2 are lower than in subjects with Parkinson’s disease and Huntington’s disease [6]. Another biomechanical study regarding the minimum foot clearance variability in the elderly during walking indicated increased irregularities and randomness in the gait patterns for individuals with balance problems and a history of falls, as an indication of loss of gait control mechanism [21]. Additionally, the Poincare indices SD1 (the short-term variability) and SD2 (the long-term variability) of the gait rhythm and the timing of the gait cycle can be readily employed to discern subjects with normal motor control from subjects with neurodegenerative disorder [22].

Another application of the Poincaré plot method is to analyze the center of pressure patterns during various sports-specific movements [24].

In conclusion, the Poincaré plot is used in clinical practice for the analysis of physiological time series, which are usually expressed as lengths, volumes, time intervals, pressures or concentrations of substances [7, 14, 16, 17, 23]. These parameters can be recorded during rest but also during exercise or other stress exposures [25, 26]. Although exercise induces fatigue, the parameters remain useful for the evaluation of human adaptation to physical effort.

The perspective of applying the Poincaré plot for studying hand grip strength variability as an entropic biomarker of aging

From a thermodynamic point of view, the aging of an organism, as an open biological system, can be compared to a slow process with nonlinear dynamics of accumulation of molecular clutches and loss of complexity of repetitive structures (fractals), namely, the growth of whole-body entropy content [27]. Any dysfunction of the body or disease state also leads to increased entropy [28] and possibly to the intensification of the aging rate.

The Poincaré plot method can be used for both qualitative and quantitative assessment of self-similarity in usually periodic functions, hence the idea of the application to the study of homeostasis of living organisms. Therefore, taking into account the entropic nature of the homeostatic equilibrium [29], we consider innovative the proposal to use biomarkers of aging that reflect complex repetitive biomechanical functions that can be quantified by mathematical modeling.

In practice, hand grip strength (HGS) has wide usefulness for the standardized determination of the individual’s health and level of functionality, the impact of morbidity/disability, or the appreciation of the dynamics of the aging process [30]. In a recent study, we also demonstrated the applicability of HGS as a parameter for mathematical modeling for the study of the process of aging [31].

Classically, HGS is determined by limited procedures in terms of the number of repetitions (ordinarily, 1–3 repetitions), the highest recorded value of which is taken. Another proposed variant is the determination of the fatigue of the hand during isometric efforts of clamping of the dynamometer in various anatomical positions [32].

Very few studies have focused on repetitive tests of HGS, for example, for the analysis of endurance, muscle fatigue and hand weakness [33, 34].

Methods

Premises and aim of the study

From the analysis of numerous scientific data, it can be concluded that hand functionality can be correlated with the state of the human body as a biological system exposed to various forms of ontogenetic stress. Therefore, we considered using the Poincaré plot method to analyze the variability of HGS during repetitive tests for healthy subjects belonging to two age groups (young and old). By comparing the data series, we can draw conclusions on the dynamics of the normal aging process, the new test design having possible worth as an entropic biomarker of the aging process.

Participants and type of study

An observational cross-sectional study was performed on two groups of healthy subjects. The first group consisted of 80 young adults aged 18–22 years (mean age 20.01 years), and the second group consisted of 80 older people aged 65–69 years (mean age 67.13 years). The sex ratio was 1:1 for both groups of subjects.

Young adults were selected from among the students of the University of Pitesti and older people from among community-dwelling people. All participants, at the time of testing, had a good health status, were completely autonomous in activities of daily living (ADL) and did not have a significant pathological history (chronic or acute pathology of the upper limbs, recent injuries, arthritis, neuromuscular disorders or other medical conditions that could interfere with HGS). Subjects were untrained individuals with previous experience with light or moderate leisure physical activity. For each individual, we recorded the informed consent to participate in the study in accordance with the ethics of research on human subjects. Ethics approval was obtained from the Ethics Committee of the Research Center for Promoting Excellence in Professional Training, University of Pitesti (reference number 836/20.04.2018).

Data acquisition

The study was performed over 9 months in 2018. Through anamnesis, we collected personal information from each participant regarding the health status and previous medical history. Next, for each of them, we assessed the HGS alternatively for both hands using a hydraulic hand dynamometer (Saehan model, MSD Europe bvba, Belgium). The results were recorded in kilogram-force (kgf). This type of device has good references for clinical use, in terms of validity and reliability, similar to the hydraulic Jamar dynamometer [35].

According to classical recommendations for obtaining maximal HGS results, participants sat on a chair, with feet flat on the floor, with the elbow flexed at 90°, the forearm in a neutral position and the wrist between 0° and 30° of extension [36]. Basically, the goal was to choose a position as comfortable as possible for each subject within the mentioned interval. This fact is in accordance with the recommendations for optimal dynamometer handle position to assess maximal isometric HGS in epidemiological studies and with the recommendations of the American Society of Hand Therapist [36].

As a standard procedure, the dynamometer’s base must be applied on the first metacarpal bone (inside the palm), with the handle in contact with half of the last four fingers. To fit each individual’s palm size, the dynamometer’s handle was adjusted for each subject (the handle allows fine adjustment, from 3.8 cm to 8.9 cm, in 5 steps).

For each hand, 60 successive tests were performed over an 8-min interval in the form of repeated maximal isometric efforts, with a duration of 3 s each, followed by a relaxation phase of 5 s (when the result was read). No other body movement was allowed during testing. The subjects were encouraged to reach the maximal results, this condition requiring a high concentration on the task. Our protocol was designed by starting from the classic recommendations for clinical determination of HGS regarding the duration of maximal isometric effort [37]. For the determination of hand grip endurance with repetitive maximal isometric contractions, some authors have used 2.5 s for contractions and 1 s for rest time [38]. In our case, a higher value of the pause (5 s) was proposed to reduce muscle fatigue. For this reason, the selected number of 60 successive tests is relatively easy for healthy subjects to do and does not cause excessive fatigue.

To ensure a uniform test pace and to assist the subjects, we used a sensory multimedia support with visual and acoustic feedback. Hence, on a digital display (smartphone or tablet), we ran a .gif file to synchronize the testing phases with the rest in the form of a countdown timer. Initially, the dominant hand, considered to be the one preferred for ADL (writing), was tested. Next, the procedure was repeated for the nondominant hand after a 5-min break. Classically, a pause of at least 1 min is recommended between the two tests [37]. In our case, a 5-min extended pause between the measurements with the dominant and nondominant hands was selected to ensure that the fatigue from the measurement of the one hand did not influence the other hand.

Each subject performed a short familiarization trial (4–5 HGS contractions) 5 min before the main testing to familiarize themselves with the procedure. The testing started from the resting state, without a warm-up session. This was motivated by the fact that the increase in HGS due to warm-up could be clinically significant [39].

Common anthropometric measurements (body height, H; body mass, M) were also performed according to standard procedures. All assessments were completed in the morning, between 8 and 11 a.m.

Outcomes and statistical analysis

Data series of HGS were grouped by sex, age (young, older people), and laterality (dominance of the hand). For statistical analysis, we applied univariate descriptive statistics and inferential statistics. Therefore, we initially calculated the mean HGS and the Poincaré indices SD1, SD2, SD1/SD2 and AFE for each subject and for each hand. Starting from the H and W values, we also calculated the body mass index (BMI) for each participant. We defined another parameter, the effect of fatigue, as an average decrease in HGS, as a percentage change between the first and the last evaluation in the set of 60 tests.

Next, we determined the mean and standard deviation (SD) for the young and older groups (men, women, men and women together). As examples, we plotted the Poincaré graphs for one subject of each group.

The data series was checked for normality by means of the Shapiro–Wilk test, and since all of the data presented a nonnormal distribution, we applied the Mann–Whitney U-test for independent large samples (N > 20) to check the statistical significance of the differences between groups (calculation of the U and z values).

To evaluate the magnitude of the difference between groups, we determined the effect size coefficient r with the following formula: r \( =\frac{\mathrm{z}}{\surd \mathrm{n}} \), where n is the number of subjects [40]. The interpretation of the r coefficient is as follows: values greater than 0.5 denote a large effect size, values in the range of 0.3–0.5 indicate a medium effect size, and values smaller than 0.1 indicate a small effect size [41]. Finally, we run a simple linear regression model for the analyzed variables.

Results

The results are centralized as descriptive statistical indicators in Tables 1 and 2. It is noteworthy that the statistical indicators for HGS, in all situations, could be included in normative data according to sex and laterality for the concerned age groups [42, 43]. Interpretations should be made by noting that the mean values of HGS for the study groups refer to the series of values obtained by 60 successive measurements for each participant’s hand.

Table 1 Statistic indicators for investigated parameters in the young groups
Table 2 Statistic indicators for investigated parameters in the older groups

Clearly, during HGS serial testing, the HGS values tended to decrease gradually due to the phenomenon of muscle fatigue. Therefore, the maximum values during these successive measurements can be considered representative for each subject as the reference level of HGS. At the same time, the mean values of HGS indicate the fatigue over time and the adaptability to serial testing for the investigated subjects.

For the inferential statistical analysis, a nonparametric test (the Mann-Whitney U-test) was applied to compare the differences between data series with a nonnormal distribution. In fact, the existence of this type of distribution was expected, considering the temporal nonlinearity of the evolution of the parameters derived from the HGS values (Tables 3, 4 and 5).

Table 3 Comparison of recorded parameters between young and older men groups
Table 4 Comparison of recorded parameters between young and older women groups
Table 5 Comparison of recorded parameters between young and older groups

The analysis of the differences between groups revealed statistically significant results for most HGS-derived indices (p ≤ 0.05), with the exception of the ratio SD1/SD2 (for the dominant and nondominant hands), when comparing the groups of young women and older women.

In the case of statistically significant results, the magnitude of the differences between the data series indicated, in most situations, a large effect size (r > 0.5). There were also three distinct situations in which the r values indicated a medium effect size: for the SD1/SD2 ratio of the nondominant hand when comparing the groups of young men and older men and for the SD1/SD2 ratio of the dominant and nondominant hands when comparing the groups of young and older subjects.

Next, we applied a standard linear analysis of the fatigue and the Poincaré parameters. The fact that the variables do not have a normal distribution is not an impediment, and linear regression remains a statistically sound technique in studies of large sample sizes [44]. For this reason, we applied the simple linear regression at the level of young and older groups (n = 80). The results of simple linear regression analysis which was conducted to determine the effect of fatigue (the predictor variable) on the parameters measured (the outcome variables) are presented in Table 6.

Table 6 Results of the simple linear regression analysis for the effect of fatigue on recorded parameters in young and older groups

We found that our regression model is statistically significant in most cases. Therefore, a certain part of the variability of the analyzed parameters is explained by the appearance of the fatigue effect.

Discussion

At present, biological aging can best be quantified through compound aging scores, and HGS is used as a singular indicator in a classic manner as an approximate predictor of longevity, disability, frailty and/or morbidity [45, 46].

To our knowledge, the present study is the first to consider the biomechanical analysis of repetitive HGS testing through the Poincaré plot method to investigate the aging process in terms of entropy. Although there are a few studies that analyze the HGS variation during serial tests, these included relatively small series of tests, on the order of 10–15 repetitions. In most cited cases, such testing protocols have proven to be reliable [34, 47, 48]. The innovation of our study lies in designing an investigation of the HGS variability during repetitive tests for young and older subjects by using mathematical modeling of the recorded data. Thus, for each participant, a significant number of repetitions of the test was performed (60 successive tests), feasible for data analysis through the Poincaré plot method [49].

Following the dynamics of the HGS values during the serial testing of the subjects, a series of relevant observations can be made. Interestingly, in several cases, the maximum values recorded for HGS were not reached during the first 5 tests in the 60-test series. Hence, the classic recommendation to perform 3 HGS determinations, of which the highest value is selected [50, 51], is not always fully relevant to this biomechanical parameter.

Additionally, for the proposed protocol, muscle fatigue occurred in an atypical way. Thus, a nonlinear descendent trend in HGS values was observed over time, and the HGS minimum values were sometimes recorded prior to the last 5 tests. In addition, there were subjects with atypical individual evolution during the serial testing. In other words, such situations cannot be excluded, a fact already confirmed by other authors [52].

For our testing protocol, we considered the occurrence of muscle fatigue as an inherent phenomenon that decreases muscle strength. The nonlinear character of the HGS during serial testing, however, indicates the variability of the efficiency of the regulation system of the imposed motor task. Essentially, muscle fatigue, as a physiological process, involves complex systems of neuromotor and metabolic regulation and might be measured as the entropy level [53]. Additionally, fatigue is influenced by the aging process, and older adults seem to be more susceptible to fatigue during high-speed dynamic contractions [54].

Overall, in the young men group, we found a fatigue effect of 15.89% for the dominant hand and 16.87% for the nondominant hand. For the young women group, the mean values were 24.53 and 26.7%, respectively. In the older men group, the recorded mean values were 34.74 and 38.61%, and in the older women group, they were 48.09 and 53.84%, respectively. Clearly, the muscular fatigue of the hand during testing was of a general nature among the subjects, being more noticeable in women, regardless of age. Moreover, the described phenomenon was much broader in older people than young subjects, which could be explained by the decline in neuromotor functions associated with the aging process.

Analyzing the values for R squared from Table 6, we observe, as expected, that the fatigue influences more strongly the mean HGS in all situations. In the case of the parameters derived from the Poincaré plot method, there are similarities, but also differences in the relations with the fatigue, as the predictor variable. Overall, the effect of fatigue is more evident at the level of SD2, SD1/SD2, and AFE and lower at the level of SD1, for both hands and age groups. Things are plausible because SD2 reflects the long-term variability and SD1 the short-term variability. The fatigue effect mainly induces the change in the long-term variability of HGS. Also, the maximum effect of fatigue was identified in the case of SD1/SD2 for the dominant hand of older people, when 46% of the variation of the parameter is explained by the regressor fatigue.

The serial testing of the HGS determined the appearance of nonlinear oscillations of the motor performance of the subjects’ hands, with a decreasing tendency. This phenomenon can be explained by the gradual appearance of muscle fatigue and by the variability of the efficiency of the neuromotor and metabolic control mechanisms. Moreover, muscle fatigue itself reflects a failure of neuromuscular regulation and muscle metabolic adaptation in response to exercise [55]. In other words, a complex motor task (such as HGS) can be performed successively over time with a certain constant rhythm as long as the processes described above involve adaptive capabilities of the movement system. During aging, the human body, as an open biological system, manifests limitations of metabolic and functional adaptation to stress factors, which is also reflected in the decline in skeletal muscle performance and physical performance [56].

The decrement in HGS performance has been reported in other studies that have focused on identifying HGS endurance during dynamic evaluations [34, 48, 57]. Other authors consider that, at least for repeated series of 10 consecutive HGS tests, the performance in the test is quite stable over trials, although there is the expected fatigue effect, especially for men [47]. However, the literature on this topic is inconsistent when it comes to small series of repeat tests [50]. Obviously, the gradual decrease in HGS by successive testing is generally conditioned by the number of repetitions and by the intervals between them [58].

A dynamic protocol, for example, of 12 repeated maximal repetitions, is recommended for the evaluation of dynamic HGS endurance, using as reliable indicators the maximal HGS and the percentage change [59]. In our study, the objective of the data series analysis was to collaterally target the evaluation of HGS endurance, which was anticipated to occur in the proposed protocol. Instead, from an entropic perspective, we found that the mechanical time-series fluctuations of the HGS differed between the young group and the older group, regardless of sex. The obtained indices of variability, highlighted by the Poincaré plot method, were significantly higher for the older group than for the young group overall, and this difference held in the subgroups of men and women (p ≤ 0.05).

The results can be interpreted in a more refined manner by taking into account one at a time the SD1, SD2, SD1/SD2 and AFE indices. As examples, the pattern of HGS fluctuations (dominant hand) of representative subjects from the groups of young and older subjects can be observed in Figs. 1 and 2. The subjects were chosen according to the mean values of the SD1 and SD2 indices of the groups.

Fig. 1
figure 1

Typical sample of Poincaré plot of HGS fluctuations (dominant hand), for a young subject (man). HGS: hand grip strength; AFE = area of the fitting ellipse

Fig. 2
figure 2

Typical sample of Poincaré plot of HGS fluctuations (dominant hand) for an older subject (man). HGS: hand grip strength; AFE = area of the fitting ellipse

The decrease in HGS force for the young participant was 18.37% and for the old participant was 41.46%. Clearly, muscular fatigue was present in both cases and affected the old subjects more but appeared to be a nonlinear phenomenon. From the entropic perspective, fatigue was associated with greater variability of HGS in older subjects. As a consequence, the values SD1, SD2, and AFE were significantly smaller for the younger subjects than for the old ones. Mainly, the mechanisms of neuromuscular and metabolic control involved in supporting the process of achieving the imposed complex motor task, which also implies the onset of muscle fatigue, are more deficient in older people.

At the group level, the analysis of SD1 and SD2 indices argues that performance in HGS is more stable in young subjects, despite the expected fact that muscle fatigue occurred for all participants. In fact, the more noticeable changes occurred in SD2 than in SD1, which reflects the long-term variability of the time series of data.

The differences between the means of the SD1/SD2 ratio were less extensive and more difficult to interpret, but they can be presented in terms of the relative uniformity of the balance between short- and long-term variabilities of the time series of data.

Finally, significant differences between groups of young and older people, regardless of sex, were found in the AFE values. Generally, an elliptic plot indicates an oscillating system, and as the ellipse area gets smaller (the data become more concentrated), the greater the stability of the system and the lower its entropy is [60]. Conversely, as the ellipse area becomes larger (the data are more scattered), the tendency to irregularity is more pronounced, and the system has more variable behavior and higher entropy.

We demonstrated that the AFE mean values of the older people were higher than those of young individuals, both for men and women, as well as for the combined groups of men and women. In other words, the behavior of the organism during HGS testing, as a biomechanical system, signifies a lower level of entropy in young subjects compared to the older subjects. This implies the existence of more marked features of repeatability, uniformity, predictability and homogeneity of the data series in young adults, which means the system is functioning in a regime of maximum efficiency and resistance. Instead, the manifestation of the aging process involves a reduction in system performance in terms of focus on the task, coordination of movements, steady rhythm of HGS development, and earlier occurrence of muscle fatigue. In brief, overall, the degree of disorder of these elements in the context of achieving the required task signifies higher entropy in the older organism.

From the entropic perspective, hand sensorimotor function has been studied by other authors, for example, in the case of diabetes mellitus. In these patients, there was a reduced force structural complexity of the hand (lower approximate entropy values) than in healthy subjects when producing grip force during submaximal force production tasks [61]. Additionally, in other pathologies, such as stroke, the increased force variability constitutes a hallmark of arm disabilities [62]. In multiple sclerosis, the fatigability of repeated hand grip strength is correlated with disease progression [57], and aging causes an increase in the motor output variability during rapid discrete isometric contractions [63].

Clearly, in terms of entropy, the pathological and aging systems are less complex than healthy systems, and this finding has been attributed to the degraded physiological control processes [64]. The interpretation of our results converges to the same idea, showing that the proposed repetitive HGS testing evidences statistically significant differences between young and older healthy people. Through the mathematical modeling of data and the application of the concept of entropy, we provide arguments supporting this new design of HGS testing.

Limitations of the study

This study has some limitations. First, the proposed test is more complex than it seems, and the collected results can be considered significant only to the extent that the premises of rigorous testing are provided. Practically, interindividual differences can be reported regarding the participant’s involvement in meeting the requirements of the testing methodology. Second, the number of successive tests and proposed timeframes can be resized, depending on the objectives of the study and the resources of the subjects being tested. Last but not least, we did not consider variables such as the participants’ comorbidities or lifestyle that could interfere with HGS assessment. An extrapolation of the experimental design for other types of individuals, with functional limitations, should be reconsidered through a reduction of the number of serial tests and/or an increase in the pauses between contractions. In the future, by studying large samples of participants in several age groups and taking into account composite variables, the possible procedural errors can be mitigated.

Conclusions

Our results indicate that the variability of HGS during serial testing represents an efficient indicator for differentiation between young and older hand function patterns from an entropic perspective. The fatigue effect is present at the level of the dynamics of the recorded entropic parameters and should be considered as an important factor for data interpretation. Obviously, aging is manifested in the level of hand functionality through the time performance fluctuations of the task of achieving repetitive HGS. This fact can be interpreted in the sense of the functioning of the senescent organism as a system characterized by irregularity and oscillation, and therefore with the tendency to increase entropy.

In practical terms, the variability of HGS, evaluated by the new serial testing design, can be considered an attractive and relatively simple biomarker to use for gerontological studies. The method of analysis of HGS time series according to the Poincaré plot technique has the potential for development and refining in the future for extensive clinical applications as well as for the delimitation of normal and pathological aging.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author upon reasonable request.

Abbreviations

AFE:

Area of the fitting ellipse

BMI:

Body mass index

D:

Dominant

H:

Body height

HGS:

Hand grip strength

L:

Left

M:

Body mass

n:

number of subjects

ND:

Non-dominant

R:

Right

SD:

Standard deviation

References

  1. Fishman M, Jacono FJ, Park S, Jamasebi R, Thungtong A, Loparo KA, Dick TE. A method for analyzing temporal patterns of variability of a time series from Poincare plots. J Appl Physiol. 2012;113(2):297–306. https://doi.org/10.1152/japplphysiol.01377.2010.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Pincus SM, Goldberger AL. Physiological time-series analysis: what does regularity quantify? Am J Phys. 1994;266(4 Pt 2):H1643–56.

    CAS  Google Scholar 

  3. Khandoker AH, Karmakar C, Brennan M, Voss A, Palaniswami M. Quantitative Poincaré Plot. In: Poincaré plot methods for heart rate variability analysis. Boston: Springer; 2013. p. 13–23.

    Chapter  Google Scholar 

  4. van Emmerik RE, Ducharme SW, Amado AC, Hamill J. Comparing dynamical systems concepts and techniques for biomechanical analysis. J Sport Health Sci. 2016;5(1):3–13. https://doi.org/10.1016/j.jshs.2016.01.013.

    Article  PubMed  PubMed Central  Google Scholar 

  5. Karmakar CK, Khandoker AH, Gubbi J, Palaniswami M. Complex correlation measure: a novel descriptor for Poincaré plot. Biomed Eng Online. 2009;8:17. https://doi.org/10.1186/1475-925X-8-17.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Golińska AK. Poincare plots in analysis of selected biomedical signals, studies in logic. Grammar Rhetoric. 2013;35(48):117–27. https://doi.org/10.2478/slgr-2013-0031.

    Article  Google Scholar 

  7. Crenier L. Poincaré plot quantification for assessing glucose variability from continuous glucose monitoring systems and a new risk marker for hypoglycemia: application to type 1 diabetes patients switching to continuous subcutaneous insulin infusion. Diabetes Technol Ther. 2014;16(4):247–54. https://doi.org/10.1089/dia.2013.0241.

    Article  CAS  PubMed  Google Scholar 

  8. Guzik P, Piskorski J, Krauze T, Schneider R, Wesseling KH, Wykretowicz A, Wysock H. Correlations between Poincaré plot and conventional heart rate variability parameters assessed during paced breathing. J Physiol Sci. 2007;57:63–71.

    Article  PubMed  Google Scholar 

  9. Rezaei M, Mohammadi H, Khazaie H. EEG/EOG/EMG data from a cross sectional study on psychophysiological insomnia and normal sleep subjects. Data Brief. 2017;15:314–9. https://doi.org/10.1016/j.dib.2017.09.033.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Richman JS, Moorman JR. Physiological time-series analysis using approximate entropy and sample entropy. Am J Physiol Heart Circ Physiol. 2000;278(6):H2039–49.

    Article  CAS  PubMed  Google Scholar 

  11. Huo C, Huang X, Zhuang J, Hou F, Ni H, Ning X. Quadrantal multi-scale distribution entropy analysis of heartbeat interval series based on a modified Poincaré plot. Physica A. 2013;392(17):3601–9.

    Article  Google Scholar 

  12. Javorka M. Analysis of variability of physiologic parameters using the Poincare plot. Cesk Fysiol. 2002;51(2):75–81.

    CAS  PubMed  Google Scholar 

  13. Voss C, Fischer R, Schroeder A. Coupling of heart rate and systolic blood pressure in hypertensive pregnancy. Methods Inf Med. 2014;53(4):286–0.

    Article  CAS  PubMed  Google Scholar 

  14. Bien MY, Hseu SS, Yien HW, Kuo BI, Lin YT, Wang JH, Kou YR. Breathing pattern variability: a weaning predictor in postoperative patients recovering from systemic inflammatory response syndrome. Intensive Care Med. 2004;30(2):241–7. https://doi.org/10.1007/s00134-003-2073-8.

    Article  PubMed  Google Scholar 

  15. Bien MY, Shui Lin Y, Shih CH, Yang YL, Lin HW, Bai KJ, Wang JH, Ru KY. Comparisons of predictive performance of breathing pattern variability measured during T-piece, automatic tube compensation, and pressure support ventilation for weaning intensive care unit patients from mechanical ventilation. Crit Care Med. 2011;39(10):2253–62. https://doi.org/10.1097/CCM.0b013e31822279ed.

    Article  PubMed  Google Scholar 

  16. Guzik P, Piskorski J, Krauze T, Narkiewicz K, Wykretowicz A, Wysocki H. Asymmetric features of short-term blood pressure variability. Hypertens Res. 2010;33(11):1199–205. https://doi.org/10.1038/hr.2010.138.

    Article  PubMed  Google Scholar 

  17. Henriques T, Munshi MN, Segal AR, Costa MD, Goldberger AL. “Glucose-at-a-glance”: new method to visualize the dynamics of continuous glucose monitoring data. J Diabetes Sci Technol. 2014;8(2):299–306.

    Article  PubMed  PubMed Central  Google Scholar 

  18. Hayashi K, Mukai N, Sawa T. Poincaré analysis of the electroencephalogram during sevoflurane anesthesia. Clin Neurophysiol. 2015;126(2):404–11. https://doi.org/10.1016/j.clinph.2014.04.019.

    Article  PubMed  Google Scholar 

  19. Bajestani GS, Golpayegani MRH, Sheikhani A, Ashrafzadeh F. Poincaré section analysis of the electroencephalogram in autism spectrum disorder using complement plots. Kybernetes. 2017;46(2):364–82. https://doi.org/10.1108/K-12-2015-0306.

    Article  Google Scholar 

  20. Luginbühl M, Rüfenacht M, Korhonen I, Gils M, Jakob S, Petersen-Felix S. Stimulation induced variability of pulse plethysmography does not discriminate responsiveness to intubation. Br J Anaesth. 2006;96(3):323–9.

    Article  PubMed  Google Scholar 

  21. Khandoker AH, Palaniswami M, Begg RK. A comparative study on approximate entropy measure and Poincaré plot indexes of minimum in the elderly during walking. J Neuroeng Rehabil. 2008;5:4. https://doi.org/10.1186/1743-0003-5-4.

    Article  PubMed  PubMed Central  Google Scholar 

  22. Kamath C. Loss of lag response curvilinearity of gait poincare plot indices in neurodegenerative disorders. Open Access Library J. 2015;2(6):1–11. https://doi.org/10.4236/oalib.1101571.

    Article  Google Scholar 

  23. Sivakumarana S, Schinkel-Ivya A, Masania K, Mansfielda A. Relationship between margin of stability and deviations in spatiotemporal gait features in healthy young adults. Hum Mov Sci. 2018;57:366–73. https://doi.org/10.1016/j.humov.2017.09.014.

    Article  Google Scholar 

  24. Ball K, Best R, Dowlan S. Non-linear analysis of centre of pressure patterns in the golf swing – Poincare plots, XXV ISBS Symposium 2007. Ouro Preto: Open Journal Systems; 2007. p. 180–3.

  25. Platiša MM, Bojić T, Mazić S, Kalauzi A. Generalized Poincaré plots analysis of heart period dynamics in different physiological conditions: Trained vs. untrained men. PLoS One. 2019;14(7):e0219281. https://doi.org/10.1371/journal.pone.0219281.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  26. Catai AM, Pastre CM, Godoy MF, Silva ED, Takahashi ACM, Vanderlei LCM. Heart rate variability: are you using it properly? Standardisation checklist of procedures. Braz J Phys Ther. 2019. https://doi.org/10.1016/j.bjpt.2019.02.006.

  27. Hayflick L. The future of ageing. Nature. 2000;208:267–9. https://doi.org/10.1038/35041709.

    Article  CAS  Google Scholar 

  28. Sturmberg JP, Bennett JM, Picard M, Seely AAJE. The trajectory of life. Decreasing physiological network complexity through changing fractal patterns. Front Physiol. 2015;6:169. https://doi.org/10.3389/fphys.2015.00169.

    Article  PubMed  PubMed Central  Google Scholar 

  29. Shishvan SS, Vigliotti A, Deshpande VS. The homeostatic ensemble for cells. Biomech Model Mechanobiol. 2018;17(6):1631–62. https://doi.org/10.1007/s10237-018-1048-1.

    Article  CAS  PubMed  Google Scholar 

  30. Roberts HC, Denison HJ, Martin HJ, Patel HP, Syddall H, Cooper C, Sayer AA. A review of the measurement of grip strength in clinical and epidemiological studies: towards a standardised approach. Age Ageing. 2011;40:423–9. https://doi.org/10.1093/ageing/afr051.

    Article  PubMed  Google Scholar 

  31. Iconaru EI, Ciucurel MM, Georgescu L, Ciucurel C. Hand grip strength as a physical biomarker of aging from the perspective of a Fibonacci mathematical modeling. BMC Geriatr. 2018;18:296. https://doi.org/10.1186/s12877-018-0991-0.

    Article  PubMed  PubMed Central  Google Scholar 

  32. Alkurdi ZD, Dweiri M. A biomechanical assessment of isometric handgrip force and fatigue at different anatomical positions. J Appl Biomech. 2010;26(2):123–33.

    Article  PubMed  Google Scholar 

  33. Tredgett MW, Davis TR. Rapid repeat testing of grip strength for detection of faked hand weakness. J Hand Surg (Br). 2000;25(4):372–5.

    Article  CAS  Google Scholar 

  34. Gerodimos V, Karatrantou K, Psychou D, Vasilopoulou T, Zafeiridis A. Static and dynamic handgrip strength endurance: test-retest reproducibility. J Hand Surg Am. 2017;42(3):e175–84. https://doi.org/10.1016/j.jhsa.2016.12.014.

    Article  PubMed  Google Scholar 

  35. Reis MM, Arantes PMM. Assessment of hand grip strength - validity and reliability of the Saehan dynamometer. Fisioter Pesqui. 2011;18(2):176–81. https://doi.org/10.1590/S1809-29502011000200013.

    Article  Google Scholar 

  36. Trampisch US, Franke J, Jedamzik N, Hinrichs T, Platen P. Optimal Jamar dynamometer handle position to assess maximal isometric hand grip strength in epidemiological studies. J Hand Surg Am. 2012;37(11):2368–73. https://doi.org/10.1016/j.jhsa.2012.08.014.

    Article  PubMed  Google Scholar 

  37. Gąsior JS, Pawłowski M, Williams CA, Dąbrowski MJ, Rameckers EA. Assessment of Maximal Isometric Hand Grip Strength in School-aged Children. Open Med (Wars). 2018;13:22–8.

    Article  Google Scholar 

  38. Wallström A, Nordenskiöld U. Assessing hand grip endurance with repetitive maximal isometric contractions. J Hand Ther. 2001;14(4):279–85.

    Article  PubMed  Google Scholar 

  39. Marion R, Niebuhr BR. Effect of warm-up prior to maximal grip contractions. J Hand Ther. 1992;5(3):143–6. https://doi.org/10.1016/S0894-1130(12)80349-8.

    Article  Google Scholar 

  40. Fritz CO, Morris PE, Richler JJ. Effect size estimates: current use, calculations, and interpretation. J Exp Psychol Gen. 2012;141(1):2–18. https://doi.org/10.1037/a0024338.

    Article  PubMed  Google Scholar 

  41. Coolican H. Research methods and statistics in psychology. London: Hodder Education; 2009. p. 395.

    Google Scholar 

  42. Massy-Westropp NM, Gill TK, Taylor AW, Bohannon RW, Hill CT. Hand grip strength: age and gender stratified normative data in a population-based study. BMC Res Notes. 2011;4:127. https://doi.org/10.1186/1756-0500-4-127.

    Article  PubMed  PubMed Central  Google Scholar 

  43. Dodds RM, Syddall HE, Cooper R, Benzeval M, Deary IJ, Dennison EM, Der G, Gale CR, Inskip HM, Jagger C, Kirkwood TB, Lawlor DA, Robinson SM, Sayer AA. Grip strength across the life course: normative data from twelve British studies. PLoS One. 2014;9(12):e113637. https://doi.org/10.1371/journal.pone.0113637.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  44. Li X, Wong W, Lamoureux EL, Wong TY. Are linear regression techniques appropriate for analysis when the dependent (outcome) variable is not normally distributed? Invest Ophthalmol Vis Sci. 2012;53(6):3082–3. https://doi.org/10.1167/iovs.12-9967.

    Article  PubMed  Google Scholar 

  45. Shamir L. Composite aging markers can be used for quantitative profiling of aging. Gerontology. 2015;62(1):66–8. https://doi.org/10.1159/000433466.

    Article  CAS  PubMed  Google Scholar 

  46. Ding YY, Kuha J, Murphy M. Multidimensional predictors of physical frailty in older people: identifying how and for whom they exert their effects. Biogerontology. 2017;18(2):237–52. https://doi.org/10.1007/s10522-017-9677-9.

    Article  PubMed  PubMed Central  Google Scholar 

  47. Reddon JR, Stefanyk WO, Gill DM, Renney C. Hand dynamometer: effects of trials and sessions. Percept Mot Skills. 1985;61:1195–8.

    Article  CAS  PubMed  Google Scholar 

  48. White C, Dixon K, Samuel D, Stokes M. Handgrip and quadriceps muscle endurance testing in young adults. SpringerPlus. 2013;2:451. https://doi.org/10.1186/2193-1801-2-451.

    Article  PubMed  PubMed Central  Google Scholar 

  49. Gomes RL, Vanderlei LC, Garner DM, Santana MD, de Abreu LC, Valenti VE. Poincaré plot analysis of ultra-short-term heart rate variability during recovery from exercise in physically active men. J Sports Med Phys Fitness. 2018;58(7–8):998–1005. https://doi.org/10.23736/S0022-4707.17.06922-5.

    Article  PubMed  Google Scholar 

  50. Patterson RP, Baxter T. A multiple muscle strength testing protocol. Arch Phys Med Rehabil. 1988;69:366–8.

    CAS  PubMed  Google Scholar 

  51. Reijnierse EM, de Jong N, Trappenburg MC, Blauw GJ, Butler-Browne G, Gapeyeva H, Hogrel JY, McPhee JS, Narici MV, Sipilä S, Stenroth L, van Lummel RC, Pijnappels M, Meskers CGM, Maier AB. Assessment of maximal handgrip strength: how many attempts are needed? J Cachexia Sarcopenia Muscle. 2017;8(3):466–74. https://doi.org/10.1002/jcsm.12181.

    Article  PubMed  PubMed Central  Google Scholar 

  52. Mathiowetz V. Effect of three trials on grip and pinch strength measurement. J Hand Ther. 1990;3:195–8.

    Article  Google Scholar 

  53. Sung PS, Zurcher U, Kaufman M. Gender differences in spectral and entropic measures of erector spinae muscle fatigue. J Rehabil Res Dev. 2008;45(9):1431–9.

    Article  PubMed  Google Scholar 

  54. Kent-Braun JA. Skeletal muscle fatigue in old age: whose advantage? Exerc Sport Sci Rev. 2009;37(1):3–9. https://doi.org/10.1097/JES.0b013e318190ea2e.

    Article  PubMed  PubMed Central  Google Scholar 

  55. Wan J, Qin Z, Wang P, Sun Y, Liu X. Muscle fatigue: general understanding and treatment. Exp Mol Med. 2017;49(10):e384. https://doi.org/10.1038/emm.2017.194.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  56. Tieland M, Trouwborst I, Clark BC. Skeletal muscle performance and ageing. J Cachexia Sarcopenia Muscle. 2018;9(1):3–19. https://doi.org/10.1002/jcsm.12238.

    Article  PubMed  Google Scholar 

  57. Severijns D, Lamers I, Feys P. Hand grip fatigability in persons with multiple sclerosis according to hand dominance and disease progression. J Rehabil Med. 2015;47(2):154–60. https://doi.org/10.2340/16501977-1897.

    Article  PubMed  Google Scholar 

  58. Watanabe T, Owashi K, Kanauchi Y, Mura N, Takahara M, Ogino T. The short-term reliability of grip strength measurement and the effects of posture and grip span. J Hand Surg Am. 2005;30(3):603–9.

    Article  PubMed  Google Scholar 

  59. Karatrantou K. Dynamic handgrip strength endurance: a reliable measurement in older women. J Geriatr Phys Ther. 2018. https://doi.org/10.1519/JPT.0000000000000180.

    Article  PubMed  Google Scholar 

  60. Kovatchev B, Cobelli C. Glucose variability: timing, risk analysis, and relationship to hypoglycemia in diabetes. Diabetes Care. 2016;39(4):502–10. https://doi.org/10.2337/dc15-2035.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  61. Ochoa N, Gorniak SL. Changes in sensory function and force production in adults with type II diabetes. Muscle Nerve. 2014;50:984–90. https://doi.org/10.1002/mus.24261.

    Article  PubMed  Google Scholar 

  62. Lodha N, Misra G, Coombes SA, Christou EA, Cauraugh JH. Increased force variability in chronic stroke: contributions of force modulation below 1 Hz. PLoS One. 2013;8(12):e83468. https://doi.org/10.1371/journal.pone.0083468.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  63. Christou EA, Carlton LG. Old adults exhibit greater motor output variability than young adults only during rapid discrete isometric contractions. J Gerontol A Biol Sci Med Sci. 2001;56(12):B524–32. https://doi.org/10.1093/gerona/56.12.B524.

    Article  CAS  PubMed  Google Scholar 

  64. Cashaback JG, Cluff T, Potvin JR. Muscle fatigue and contraction intensity modulates the complexity of surface electromyography. J Electromyogr Kinesiol. 2013;23(1):78–83. https://doi.org/10.1016/j.jelekin.2012.08.004.

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

Not applicable.

Funding

There are no sources of funding.

Author information

Authors and Affiliations

Authors

Contributions

Conception and design of the research: EII, CC; acquisition of data: EII, CC; analysis and interpretation of the data: EII, CC; statistical analysis: EII, CC; drafting of the manuscript: EII, CC; critical revision of the manuscript for important intellectual content: EII, CC. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Elena Ioana Iconaru.

Ethics declarations

Ethics approval and consent to participate

The study was approved by the Ethics Committee of the Research Center for Promoting Excellence in Professional Training (reference number 836/20.04.2018), University of Pitesti. Participants gave written informed consent before inclusion in the study.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Iconaru, E.I., Ciucurel, C. Hand grip strength variability during serial testing as an entropic biomarker of aging: a Poincaré plot analysis. BMC Geriatr 20, 12 (2020). https://doi.org/10.1186/s12877-020-1419-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12877-020-1419-1

Keywords