Skip to main content

Table 3 Screening performance of HHIE-ST at different cut-off points

From: The effective screening tools for detecting hearing loss in elderly population: HHIE-ST Versus TSQ

AUC at different severity of hearing loss

(95% CI)

HHIE-ST cut-off

True-positive rate

(Sensitivity)

Specificity

LR+

LR-

0.74

(0.70–0.77)

> 25 dB

( > = 10 )

74.01

58.59

1.79

0.44

( > = 12 )

70.32

62.96

1.90

0.47

( > = 14 )

66.50

68.35

2.10

0.49

( > = 16 )

64.16

73.40

2.41

0.49

0.80

(0.78–0.83)

> 40 dB

( > = 10 )

88.96

52.19

1.86

0.21

( > = 12 )

86.84

57.37

2.04

0.23

( > = 14 )

83.01

61.91

2.18

0.27

( > = 16 )

81.95

66.46

2.44

0.27

0.82

(0.80–0.86)

> 60 dB

( > = 10 )

100

38.85

1.63

0

( > = 12 )

100

43.19

1.76

0

( > = 14 )

98.31

47.73

1.88

0.03

( > = 16 )

97.46

51.06

1.99

0.04