Skip to main content

Table 3 Sensitivity, specificity and predictive values for RMA and its components. TP– true positive; FP– false positive; TN– true negative; FN– false negative; CI– confidence interval; Sens.- Sensitivity; Spec.- Specificity; NPV– negative predictive value; PPV– positive predictive value. N = 384; 4AT positive = 98; 4AT negative = 286

From: Validation of a viable delirium detection test performed by nurses and physicians during routine patient care

 

TP

(n)

FP

(n)

TN

(n)

FN

(n)

Sens. %

(95% CI)

Spec. %

(95% CI)

NPV %

(95% CI)

PPV %

(95% CI)

RADAR

94

104

182

4

95.8

92.0, 99.8))

63.6

58.1, 69.2))

97.8

95.8, 99.9))

47.5

(40.5, 54.4)

RADAR + MOYB

92

80

206

6

93.9

(89.1, 98.6)

72.0

(66.8, 77.2)

97.2

(94.9, 99.4)

53.5

(46.0, 60.9)

RMA

92

5

281

6

93.9

(89.1, 98.6)

98.3

(96.7, 99.8)

97.9

(96.3, 99.6)

94.8

(90.4, 99.2)